At B&B Heating & Cooling, Inc., we install and service all brands of central air conditioning and cooling systems in Homer glen, IL. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Homer glen, IL.

Let us help you decide how best to solve your air conditioning needs today.


Repaired pilot for Carrier Furnace.

Homer Glen, IL
03-15-2019


Repair leak in copper radiant line. Found FB-38 not feeding water when trying to bleed systm, replaced FB-38. Then #30 expansion tank started leaking and scrubber was blocked. Replace tank and scrubber.

Homer Glen, IL
03-18-2019


Found a nest, compressor wires & 2-wire needed repair. Condenser fan was not running. Replaced capacitor & repaired wires.. Unit was fully operational at departure.

Homer Glen, IL
05-29-2019


Conducted Spring PM. Checked air filter, cleaned condenser and checked refrigerant charge. AC fully operational at departure.

Homer Glen, IL
06-04-2019


Rodent bedding causing contactor not to close. Removed bedding, checked refrigerant charge. Added 1 lb. of R-22 refrigerant. AC fully operational at departure.

Homer Glen, IL
06-11-2019

Trane 4TTX6048E
Conducted Spring PM on one Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser.
Homer Glen, IL
06-13-2019

Armstrong HVAC 4SCU14LE148P
Conducted Spring PM on one Armstrong unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.
Homer Glen, IL
06-19-2019

4SCU14LE148P
Conducted Spring PM on two Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser. Both AC fully operational at departure.

Homer Glen, IL
07-29-2019

starstarstarstarstar
5 Star Rating
4SCU14LE148P
Conducted Spring PM on 2 Trane units. Inspected refrigerant levels and electrical components and cleaned condenser. Both AC fully operational at departure.

Homer Glen, IL
07-29-2019

starstarstarstarstar
5 Star Rating
4SCU14LE148P
Installed a Trane XR13 4-Ton (R410A) condenser along with a Trane 4-Ton Matched Acoil. Flushed the exisitng refrigerant lines, installed new electrical whip between the existing disconnect box and the new AC condenser. Set the new AC Condenser on a New Rigid Poly Condenser Pad

Homer Glen, IL
08-07-2019

4SCU14LE148P
Found both Condensing systems not operating properly due to a pitted contactor and over charged units. Replaced main floor contactor and recovered refrigerant from both units. Also added on leak stop to main floor and replaced 2nd floor condenser fan motor

Homer Glen, IL
08-21-2019

4SCU14LE148P
Added 2lbs. of R410A and Easy Seal.

Homer Glen, IL
08-21-2019