Service





B&B Heating & Cooling, Inc.starstarstarstarstar4.8 / 5

47 Total Reviews /files//bb-heating-cooling-logo.png708-403-2276$13010 W 159th St Ste 1, Homer Glen IL




Oak Lawn, Illinois

Get Your Quote Today



B&B Heating & Cooling, Inc. Oak Lawn, Illinois



Recent Oak Lawn, Illinois by B&B Heating & Cooling, Inc.

Trane BTD730A100B0

Upon arrival the Tech. found the Trane R22 AC System from 1987 was not working due to having No Refrigerant in the AC System. * Based upon both Age as well as the System being an R22 System we recommend replacement with a Lennox 3-Ton 13 SEER (R410A) Condenser, a matched 3-Ton A-Coil, Fabricate and Install a Custom Sheet Metal Transition to accommodate the new A-Coil, Flush the existing refrigerant lines, Replace the Electrical Whip at the New AC Condenser, Set the Condenser on the existing AC Pad, and Pressure Test, Pump into Vacuum, and Check that the AC System is at Manufacturers Refrigerant Specification.
Oak Lawn, IL
08-16-2019

Carrier 38TZA0303

Upon arrival the Tech. found the Carrier AC system not operating properly due to low refrigerant levels. Added 1lb. of R-410A Refrigerant. The AC system was fully operational at departure.
Oak Lawn, IL
08-16-2019

Lennox 13ACX-024

Upon arrival the Tech. found the Lennox AC system not operating properly due to low refrigeratn levels. Added 2lbs. of R-410A Refrigerant. The AC system was fully operational at departure.
Oak Lawn, IL
08-16-2019

Goodman CKC24-1H

Upon arrival the Tech. found the Goodman AC system not operating properly due to a bad capacitor. Replaced the Capacitor. Also, chemically cleaned the condenser. The AC was fully operational at departure.
Oak Lawn, IL
08-12-2019

Carrier CA13NA048

Upon arrival the Tech. found the Carrier Ac unit from 2013 not operating properly due to a faulty 40+5 Capacitor. From the unit trying to run it tripped the internal overload on the compressor. Cooled down the compressor with water to reset overload. The AC was fully operational at departure.
Oak Lawn, IL
08-12-2019