AC Cooling and Air Conditioning Systems





B&B Heating & Cooling, Inc.starstarstarstarstar4.8 / 5

31 Total Reviews B&B Heating & Cooling, Inc.708-403-2276$13010 W 159th St Ste 1, Homer Glen IL




AC Cooling and Air Conditioning Systems Orland park, Illinois

At B&B Heating & Cooling, Inc., we install and service all brands of central air conditioning and cooling systems in Orland park, IL. If you have an existing cooling system our trained staff can diagnosis your AC system and recommend terrific new high efficiency choices. We offer same day evaluation and prompt air conditioning installation services Orland park, IL.

Let us help you decide how best to solve your air conditioning needs today.


Installed Honeywell Round thermostat.

Orland Park, IL
03-14-2019


Replacement of a thermostat with a Lyric T-6 Pro Wifi thermostat.

Orland Park, IL
03-15-2019


Install a New State 50 gal HWH

Orland Park, IL
03-15-2019


Found furnace not operating properly due to a clogged condensate drain. Cleaned the furnace

Orland Park, IL
03-15-2019

starstar
2 Star Rating

Installed one condensate pump.

Orland Park, IL
03-18-2019


Diccovered furnace inoperable due to a blown E.C.M module. Replaced E.C.M module

Orland Park, IL
03-18-2019


Cleaned boiler and replaced thermocouple

Orland Park, IL
03-25-2019


Upon arrival the Tech. found the Lennox Furnace from 2015 not operating properly due to a dirty flame sensor. Cleaned the furnace and cycled the system. Furnace is now operating properly. Also, The mechanical room does not have adequate airflow. Recommending different bifold doors to allow more airflow into mechanical room.

Orland Park, IL
03-29-2019


Conducted Spring Preventative Maintenance. Checked refrigerant levels, electrical components and cleaned the condenser.

Orland Park, IL
05-22-2019

Trane 4TTX6048C1000A
Conducted Spring PM on the AC system. Checked refrigerant levels, electrical components and cleaned condenser. AC was fully operational at departure.
Orland Park, IL
05-24-2019

starstarstarstarstar
5 Star Rating
Trane 4TTR3036*
Conducted Spring PM on the AC system. Checked refrigerant levels, electrical components and cleaned condenser. AC was fully operational at departure.
Orland Park, IL
05-24-2019

4TTR3036*
Conducted Spring PM on the AC system. Checked refrigerant levels, electrical components and cleaned condenser. AC was fully operational at departure.

Orland Park, IL
05-29-2019

Trane TTR048D*
Conducted Spring PM on the AC system. Checked refrigerant levels, electrical components and cleaned condenser. AC was fully operational at departure.
Orland Park, IL
05-29-2019

TTR048D*
Conducted Spring PM. Checked air filter, cleaned condenser and checked refrigerant charge. AC fully operational at departure.

Orland Park, IL
06-04-2019

TTR048D*
Conducted Spring PM. Checked air filter, cleaned condenser, and checked refrigerant charge

Orland Park, IL
06-04-2019

TTR048D*
Furnace doors were off, door switch open. Install doors, AC runs. No charge

Orland Park, IL
06-04-2019

TTR048D*
Conducted Spring PM on one Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser.

Orland Park, IL
06-11-2019

Lennox 13ACX-036
Upon arrival the Tech. found the Lennox AC system not operating properly due to a bad capacitor. Replaced the capacitor and checked refrigerant levels. The AC system was fully operational at departure.
Orland Park, IL
06-12-2019

13ACX-036
Upon arrival the Tech. inspected and adjusted dampers. *The low air flow is due to ducting in slab area is full of water and all other areas had closed dampers.* Prior vendor appears to have sanitized the ducts but failed to remove the ground water.

Orland Park, IL
06-12-2019

Ruud UAKA-048JAZ
Conducted Spring PM on one Ruud unit. Inspected refrigerant levels and electrical components and cleaned condenser.
Orland Park, IL
06-13-2019

Bryant 561CJ030*
Conducted Spring PM on one Bryant unit. Inspected refrigerant levels and electrical components and cleaned condenser.Added 2 lbs. Refrigerant
Orland Park, IL
06-14-2019

starstarstarstarstar
5 Star Rating
Trane TTR030C*
Conducted Spring PM on one Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser
Orland Park, IL
06-14-2019

Trane 4TTR3024*
Conducted Spring PM on one Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.
Orland Park, IL
06-18-2019

Armstrong HVAC 4SCU14LE130P
Conducted Spring PM on one Armstrong unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.
Orland Park, IL
06-19-2019

starstarstarstarstar
5 Star Rating
4SCU14LE130P
Conducted Spring PM on one Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.

Orland Park, IL
06-27-2019

4SCU14LE130P
Conducted Spring PM on one York unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.

Orland Park, IL
06-27-2019

Trane 4TTR4030
Found unit low on R-410A refrigerant. Charged system w/ two lbs. of R-410A
Orland Park, IL
06-27-2019

4TTR4030
Conducted Spring PM on one York unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.

Orland Park, IL
06-27-2019

4TTR4030
Installation of a Trane XR13 3-ton (R410A) AC Condenser & Cased A-coil, Flush the exisitng Refrigerant Lines and Install a new Electrical Whip between the Disconnect BOx and the NEw AC Condenser

Orland Park, IL
06-27-2019

4TTR4030
Conducted Spring PM on one Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure. And cleaned Electronic Air Cleaner

Orland Park, IL
07-09-2019

4TTR4030
Conducted Spring PM on one Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.

Orland Park, IL
07-09-2019

starstarstarstarstar
5 Star Rating
4TTR4030
Removed condenser assembly and test operation. System 2.5 lbs. low on R410A. Charge system to correct superheat

Orland Park, IL
07-09-2019

4TTR4030
Upon arrival the Tech. found the Carrier AC system from 2013 was operating properly. Found thermostat faulty. Replaced Thermostat, and checked operations. The AC System was fully operational at deeparture.

Orland Park, IL
07-23-2019

4TTR4030
Upon arrival the Tech. found the Thermostat loose onn the Sub-base, also "Y" wire at sub-base had been pulled out. Repaired the "Y" Terminal on Sub-base and Re-attached Y wire. Tested operations and the AC System was fully operational at departure.

Orland Park, IL
07-29-2019

4TTR4030
Upon arrival the Tech. found the BDP AC System inoperable due to a blown capacitor. Replaced the capacitor. The AC System was fully operational at departure.

Orland Park, IL
07-29-2019

4TTR4030
Upon arrival the Tech. found the Amana AC unit from 2010 with a block of ice found on the A-coil, thawed out AC system. Also found the condenser badly blocked and chemically cleaned the condenser. Checked Freon charge, it was low, performed a electronic leak check and found no leak. Added 2 pounds of R410 refrigerant to get system to required super heat. AC was fully operational ar departure.

Orland Park, IL
07-31-2019

4TTR4030
Upon arrival the Tech. found the Carrier AC system not operating due to the Thermostat not calling for "Cool" mode because of a loose pin on the back of the Thermostat. Replaced thermostat. The unit was fullay operational at departure.

Orland Park, IL
08-06-2019

4TTR4030
Upon arrival the Tech. found the thermostat not calling for AC. Needed to adjust and program thermostat settings. Also instructed resident on programming thermostat. Thermostat and AC system were fully operational at departure.

Orland Park, IL
08-07-2019

4TTR4030
Conducted Spring PM on one Trane unit. Inspected refrigerant levels and electrical components and cleaned condenser. AC fully operational at departure.

Orland Park, IL
08-07-2019

Carrier 24ABB330
Upon arrival the Tech. found the AC system not operating properly due to the Condenser being blocked. Chemically Cleaned the Condenser. Checked the Freon Levels and noticed the Freon Levels were low. Added 1lb. of R-410A Refrigerant. The AC system was fully operational at departure.
Orland Park, IL
08-16-2019

24ABB330
Upon arrival the Tech. found the Trane Condensing system not draining properly due to a clogged condensate. Purged compressed air through the condensate to clear all clogs and debris. The AC system was fully operational at departure.

Orland Park, IL
08-16-2019

24ABB330
Upon arrival the Tech. found the AC unit working properly and the Furnace not making nay noise. The Tech. found the noise is coming from the smoke alarm due to a dead battery. The AC was fully operational at departure. *Recommend changing the batteries*

Orland Park, IL
08-16-2019

24ABB330
Upon arrival the Tech. found the AC Condenser without a Data Tag, was not cooling properly, and would not shut off. The Condenser is extremely dirty and needs to be cleaned in order to obtain accurate refrigerant pressures to charge the unit. We estimate it is 3 Lbs. low on R22 Refrigerant and that is 20+ years old. The 2nd Option would be to replace the AC System, and the Property would be properly sized with a 2-1/2 Ton AC System. Please forward your approval and advise which option to proceed with.

Orland Park, IL
08-21-2019

24ABB330
Replaced Capacitor 40/7.5

Orland Park, IL
08-21-2019

Armstrong HVAC 4SCU13LE160P-5
Conducted winter maintenance on on Armstrong furnace. Inspected controls and blower assembly. Also cleaned the unit, humidifier and replaced both the pad and furnace filter.
Orland Park, IL
09-05-2019

Rheem RAKA-030
Found unit low on R-22 Freon. Added 2lbs of R-11. The AC was fully operational at departure.
Orland Park, IL
09-17-2019