Summertime temperatures leaving you hot under the collar? In Oak lawn, IL the vast majority of homes have some sort of system to keep those indoor temperatures down in the summer. At B&B Heating & Cooling, Inc. we are residential comfort specialists. Installing or replacing central air can be a significant project, so you’ll want to get it right. Our expert air conditioner techs can evaluate you system and your needs and recommend a course of action thats best for you.

starstarstarstarstar
5 Star Rating
Central Air Conditioning Guide Oak lawn, Illinois
Replaced blower belt
Oak Lawn, IL
03-21-2019

Central Air Conditioning Guide Oak lawn, Illinois
Upon arrival the Tech. found the Trane furnace not operating properly due to a faulty Limit switch and a low flame sensor. Replaced the Main Limit switch and clenaned the furnace & flame sensor. The unit was fully operational at departure.
Oak Lawn, IL
03-27-2019

Central Air Conditioning Guide Oak lawn, Illinois
Upon arrival the Tech. found the Lennox Furnace from 2014 inoperable due to a low flame signal. cleaned the Furnace and Flame Sensor. The unit was fully operational at departure.
Oak Lawn, IL
04-02-2019

Central Air Conditioning Guide Oak lawn, Illinois
Water had drianed onto floor from A-Coil, Test condensate pump, its ok. IT Pumps and line drains - Reowrk condensate line and humidifier drain line to condensate pump. Drain line from humidifier was holding debris and blocking AC condeste from draining properly.
Oak Lawn, IL
06-11-2019

Lennox 13ACX-024
Upon arrival the Tech. found the Lennox AC system not operating properly due to low refrigeratn levels. Added 2lbs. of R-410A Refrigerant. The AC system was fully operational at departure.
Oak Lawn, IL
08-16-2019

13ACX-024
Upon arrival the Tech. found the AC ssytem not operating properly due to a faulty capacitor and dirty Condenser. Replaced the Capacitor and Chemically Cleaned the Condenser. The AC unit was fully operational at departure.

Oak Lawn, IL
08-16-2019

13ACX-024
Upon arrival the Tech. found the AC ssytem not operating properly due to a faulty capacitor and dirty Condenser. Replaced the Capacitor and Chemically Cleaned the Condenser. The AC unit was fully operational at departure.

Oak Lawn, IL
08-16-2019

13ACX-024
Upon arrival the Tech. found the AC unit tripping on the high pressure switch due to a blocked condenser. Chemically Cleaned the Condenser. The AC unit was fully operational at departure.

Oak Lawn, IL
08-16-2019

starstarstarstarstar
5 Star Rating
13ACX-024
Complaint of AC making a pounding noise when it shuts off. - Inspected all duct-runs, refrigerant levels, capacitor, blower motor, blower assembly, all electrical components.. found no equipment resonating a buzzing/cracking sound.

Oak Lawn, IL
09-19-2019