B&B Heating & Cooling, Inc. specializes in installation and replacement of all types of gas furnaces in Tinley Park, IL. We offer a wide variety of gas furnace installation and gas furnace replacement options to meet efficiency and budget needs. Our staff can diagnosis your existing systems and recommend terrific new high efficiency choices. We offer same day evaluation and prompt gas furnace installation services in Tinley Park, IL.

Let us help you decide how best to solve you gas heating problems the the installation or replacement of a gas furnace.

Get Your Quote Today



B&B Heating & Cooling, Inc. Gas Furnaces Tinley Park, Illinois



Recent Gas Furnaces Tinley Park, Illinois by B&B Heating & Cooling, Inc.

Lennox G40UH-36B-090

Upon arrival the Tech. found the furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Tinley Park, IL
02-13-2020

Lennox ML180UH110P48C

Upon arrival the Tech. found the customer had the thermostat fan set to continuously run causing the air coming out of the registers to be cool at times. Advised customer to set the fan option on auto. The Tech. also cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Tinley Park, IL
02-11-2020

Westinghouse HVAC FG7S(A/K)-072-24B

Upon arrival the Tech. found the furnace not operating properly due to a faulty Hot Rod H.S.I. The Tech replaced the Hot Rod Ignitor. The furnace was fully operational at departure.
Tinley Park, IL
02-06-2020

Lennox ML180UH090P36B

Upon arrival the Tech. found the furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Tinley Park, IL
01-07-2020

Carrier 58SSC Family Mid Efficiency Upflow Gas Furnaces

Installed an Aprilaire 700 humidifier
Tinley Park, IL
11-18-2019

Carrier 399AAZ060100

Upon arrival the Tech. found the furnace circuit board wired incorrectly. Wired the circuit board properly.
Tinley Park, IL
11-15-2019

Carrier 58CTW045-12

Conducted Winter Maitnenance on one Carrier furnace. Inspected heat exchangers, controls, blower assembly and cleaned the furnace. Changed #35 Humidifier pad.
TInley Park, IL
10-01-2019

Trane TUD040C930

Conducted Winter Maitnenance on one Trane furnace. Inspected heat exchangers, controls, blower assembly and cleaned the furnace.
Tinley Park, IL
09-23-2019

Payne PG92SAS48080B

Upon arrival the Tech. found the Payne AC system not operating properly due to a blown capacitor. Replaced the 55/5 µF capacitor and cycled the unit. The AC system was fully operational at departure.
Tinley Park, IL
08-20-2019

Carrier 58STA110**

Loose connection on 24v circuit at the molex. Secured connection fires up every time on start up. After several times, furnace shuts off 33 limit circuit open
Tinley Park, IL
03-21-2019

Carrier 58STA110**

Cleaned flame sensor last week. Unit is tripping on low flame signal again. Needed to replace flame sensor.
TInley Park, IL
03-21-2019

Carrier 58SSC Family Mid Efficiency Upflow Gas Furnaces

Found furnace inoperable due to a dirty flame sensor and loose circuit board. Cleaned the flame sensor and tighten the circuit connection.
Tinley Park, IL
03-14-2019