Gas Furnaces Tinley Park, Illinois
B&B Heating & Cooling, Inc. specializes in installation and replacement of all types of gas furnaces in Tinley Park, IL. We offer a wide variety of gas furnace installation and gas furnace replacement options to meet efficiency and budget needs. Our staff can diagnosis your existing systems and recommend terrific new high efficiency choices. We offer same day evaluation and prompt gas furnace installation services in Tinley Park, IL.
Let us help you decide how best to solve you gas heating problems the the installation or replacement of a gas furnace.
B&B Heating & Cooling, Inc. Gas Furnaces Tinley Park, Illinois
Recent Gas Furnaces Tinley Park, Illinois by B&B Heating & Cooling, Inc.
Lennox
G40UH-36B-090
Upon arrival the Tech. found the furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Tinley Park,
IL
02-13-2020
Lennox
ML180UH110P48C
Upon arrival the Tech. found the customer had the thermostat fan set to continuously run causing the air coming out of the registers to be cool at times. Advised customer to set the fan option on auto. The Tech. also cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Tinley Park,
IL
02-11-2020
Westinghouse HVAC
FG7S(A/K)-072-24B
Upon arrival the Tech. found the furnace not operating properly due to a faulty Hot Rod H.S.I. The Tech replaced the Hot Rod Ignitor. The furnace was fully operational at departure.
Tinley Park,
IL
02-06-2020
Lennox
ML180UH090P36B
Upon arrival the Tech. found the furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Tinley Park,
IL
01-07-2020
Carrier
58SSC Family
Mid Efficiency Upflow Gas Furnaces
Installed an Aprilaire 700 humidifier
Tinley Park,
IL
11-18-2019
Carrier
399AAZ060100
Upon arrival the Tech. found the furnace circuit board wired incorrectly. Wired the circuit board properly.
Tinley Park,
IL
11-15-2019
Carrier
58CTW045-12
Conducted Winter Maitnenance on one Carrier furnace. Inspected heat exchangers, controls, blower assembly and cleaned the furnace. Changed #35 Humidifier pad.
TInley Park,
IL
10-01-2019
Trane
TUD040C930
Conducted Winter Maitnenance on one Trane furnace. Inspected heat exchangers, controls, blower assembly and cleaned the furnace.
Tinley Park,
IL
09-23-2019
Payne
PG92SAS48080B
Upon arrival the Tech. found the Payne AC system not operating properly due to a blown capacitor. Replaced the 55/5 µF capacitor and cycled the unit. The AC system was fully operational at departure.
Tinley Park,
IL
08-20-2019
Carrier
58STA110**
Loose connection on 24v circuit at the molex. Secured connection fires up every time on start up. After several times, furnace shuts off 33 limit circuit open
Tinley Park,
IL
03-21-2019
Carrier
58STA110**
Cleaned flame sensor last week. Unit is tripping on low flame signal again. Needed to replace flame sensor.
TInley Park,
IL
03-21-2019
Carrier
58SSC Family
Mid Efficiency Upflow Gas Furnaces
Found furnace inoperable due to a dirty flame sensor and loose circuit board. Cleaned the flame sensor and tighten the circuit connection.
Tinley Park,
IL
03-14-2019