B&B Heating & Cooling, Inc. specializes in installation and replacement of all types of gas furnaces in Joliet, IL. We offer a wide variety of gas furnace installation and gas furnace replacement options to meet efficiency and budget needs. Our staff can diagnosis your existing systems and recommend terrific new high efficiency choices. We offer same day evaluation and prompt gas furnace installation services in Joliet, IL.

Let us help you decide how best to solve you gas heating problems the the installation or replacement of a gas furnace.

Get Your Quote Today



B&B Heating & Cooling, Inc. Gas Furnaces Joliet, Illinois



Recent Gas Furnaces Joliet, Illinois by B&B Heating & Cooling, Inc.

Lennox G40UH-48C-110

Upon arrival the Tech. found the furnace not operating due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The Tech. also noticed the Flue is leaking on and into the furnace. The Tech. checked the B-Vent for blockage and proper draft exterior. The B-Vent does have a cap and found no blackage. The furnace was fully operational at departure.
Joliet, IL
03-10-2020

Goodman GMH80803B

Upon arrival the Tech. found the furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Joliet, IL
03-10-2020

Goodman GMH81005C

Upon arrival the Tech. found the furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Joliet, IL
03-10-2020

Goodman GMS81005C

Upon arrival the Tech. found the furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Joliet, IL
03-02-2020

Carrier 59SP5A100E21--20

Upon arrival the Tech. found furnace resonating a buzzing sound due to the draft inducer motor being ceased. Replaced the draft inducer motor and cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Joliet, IL
01-28-2020

Goodman GMS80804B

Upon the arrival the Tech. found the furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The Furnace was fully operational at departure.
Joliet, IL
01-16-2020

American Standard HVAC AUD100C936

Upon arrival the Tech. found the furnace not operating properly due dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Joliet, IL
01-15-2020

Goodman GDS80804B

Upon arrival the Tech. found the Goodman furnace not operating properly due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The furnace was fully operational at departure.
Joliet, IL
12-17-2019

Goodman GMS81005C

10/31/2019 - We called the resident when we were on our way to her home. She was aware we were on our way and should be there shortly. Upon arrival the Tech. found no one home. When we called letting the resident know we were at her home, she said she forgot we were coming. A return trip was needed due to the resident not being home. -11/1/2019 - Upon arrival the Tech. found the furnace not operating properly due to a dirty furnace filter. The Tech. replaced the furance filter. The Furnace was fully operational at departure.
Joliet, IL
12-03-2019

Goodman GMH80804B

Upon arrival the Tech. found the furnace not operating properly due to a faulty ignitor. The Tech. replaced the Ignitor. The furnace was fully operational at departure.
Joliet, IL
11-14-2019

Lennox ML180UH090P36B

Complaint of the Heat not working properly - Upon arrival the Tech. found the National Comfort Products Furnace from 2007 had been submerged in water. - Due to all electronic having water damage replacement of the furnace is recommended.
Joliet, IL
10-29-2019

Bryant 345MAV048100

Upon arrival the Tech. Found furnace inoperable due to the unit not being grounded properly. Properly grounded the unit and cleaned the furnace. Furnace is now operating properly.
Joliet, IL
03-29-2019

Goodman GDH80603A

Upon arrilv the Tech. found the Goodman furnace had a low flame signal, cleaned the furnace and flame sensor. Air flow to rooms not as strong because piping is uninsulated and very long runs to far side of the house. Some supply piping has rusted through but not to those rooms. Checked heat setting and it is on the correct setting.
Joliet, IL
03-26-2019

Payne PG8MAA042090

Inducer motor seized up, won't run. Replaced inducer motor. Cleaned the furnace. Checked air filter and inducer port
Joliet, IL
03-25-2019

Lennox ML180UH070P36A

Upon arrival the Tech. found the Lennox furnace from 2014 was not working properly due to a low flame signal. Cleaned the furnace and flame sensor. The unit was fully operational at departure.
Joliet, IL
03-21-2019

Trane TUD120C954

Pressure switch preventing furnace from starting. Replaced pressure switch.
Joliet, IL
03-15-2019

American Standard HVAC AUD100C936

PM completed on furnace.
Joliet, IL
03-14-2019