Furnace Service and Repair





B&B Heating & Cooling, Inc.starstarstarstarstar4.9 / 5

40 Total Reviews B&B Heating & Cooling, Inc.708-403-2276$13010 W 159th St Ste 1, Homer Glen IL




Furnace Service and Repair Bolingbrook, Illinois

If your gas furnace in Bolingbrook, IL is not working it is likely your furnace needs repair or service. At times the fix is simple, other times it is not. Our heating and furnace service technicians have years of experience working on furnaces like yours in Bolingbrook, IL. B&B Heating & Cooling, Inc. has service vehicles on call that are fully equipped with the tools and parts necessary to get your furnace back up and operating.

Our furnace repair, furnace service or replacement pricing is very competitive. Our estimates are always firm with no hidden surprises. You can rely on B&B Heating & Cooling, Inc. to advise you properly and to do excellent work promptly. Ask us about maintenance agreements for your high efficiency furnace today.

We provide gas furnace service in Bolingbrook, IL

We provide gas furnace repair in Bolingbrook, IL

Lennox ML180UH090P48B
Upon arrival the Tech. found the Furnace not operating due to a dirty flame sensor. The Tech. cleaned the furnace and flame sensor. The Furnace was fully operational at departure.
Bolingbrook, IL
11-21-2019

Trane TUE1C100A948
Upon arrival the Tech. found the Furnace not operating due to a dirty flame sensor. The Tech. cleaned the Furnace and Flame Sensor. The Furnace was fully operational and not making a noise at departure.
Bolingbrook, IL
11-14-2019

Goodman GMS81005C
Upon arrival the Tech. found the furnace not operating properly due to the pressure switch port on the draft inducer being clogged. The Tech. cleared the pressure switch port on the draft inducer. The Furnace was fully operational at departure.
Bolingbrook, IL
11-14-2019

Westinghouse HVAC FG7T(*A/K)-060-23A
Upon arrival the Tehc. found the Thermostat set at 78 degrees and reads 71 degrees. The Tech. also found the unit had a low flame signal and tripped limit. The Tech. cleaned the Furnace and Flame Sensor, also checked the A-Coil for Blockage.
Bolingbrook, IL
11-21-2019

Lennox ML180UH110P48C
Upon arrival the Tech. found the Lennox furnace from 2014 not operating due to no flame signal. The Tech. cleaned the furnace and flame sensor. The Furnace was fully operational at departure.
Bolingbrook, IL
11-21-2019

Payne PG8MAA048110
Upon arrival the Tech. found the Payne Furnace from 2012 had a bad Inducer Motor that had locked up, the Tech. freed it up, but it is screaming and the Inducer Motor needs replacement. The Tech. replaced the Inducer Motor. The Furnace was fully operational at departure.
Bolingbrook, IL
12-03-2019

Trane TUE1B100A936
Upon arrival the Tech. found the Furnace not operating due to the unit had a 4 flash on IFC Board, open limit. All Limits were closed. The Tech. found the Molex Plug not getting a good connection to the IFC Board. The Tech removed the Molex Plug and Reconnected it to the IFC Board and flash code was removed. The Tech. also cleaned the furnace and flame sensor. The Furnace was fully operational at departure.
Bolingbrook, IL
12-02-2019